[−][src]Trait gstreamer::PipelineExt
Required methods
fn auto_clock(&self)
Let self
select a clock automatically. This is the default
behaviour.
Use this function if you previous forced a fixed clock with
PipelineExt::use_clock
and want to restore the default
pipeline clock selection algorithm.
MT safe.
fn get_auto_flush_bus(&self) -> bool
Check if self
will automatically flush messages when going to
the NULL state.
Returns
whether the pipeline will automatically flush its bus when going from READY to NULL state or not.
MT safe.
fn get_delay(&self) -> ClockTime
fn get_latency(&self) -> ClockTime
Gets the latency that should be configured on the pipeline. See
PipelineExt::set_latency
.
Returns
Latency to configure on the pipeline or GST_CLOCK_TIME_NONE
fn get_pipeline_clock(&self) -> Option<Clock>
Gets the current clock used by self
.
Unlike ElementExt::get_clock
, this function will always return a
clock, even if the pipeline is not in the PLAYING state.
Returns
a Clock
, unref after usage.
fn set_auto_flush_bus(&self, auto_flush: bool)
Usually, when a pipeline goes from READY to NULL state, it automatically flushes all pending messages on the bus, which is done for refcounting purposes, to break circular references.
This means that applications that update state using (async) bus messages (e.g. do certain things when a pipeline goes from PAUSED to READY) might not get to see messages when the pipeline is shut down, because they might be flushed before they can be dispatched in the main thread. This behaviour can be disabled using this function.
It is important that all messages on the bus are handled when the automatic flushing is disabled else memory leaks will be introduced.
MT safe.
auto_flush
whether or not to automatically flush the bus when the pipeline goes from READY to NULL state
fn set_delay(&self, delay: ClockTime)
Set the expected delay needed for all elements to perform the
PAUSED to PLAYING state change. delay
will be added to the
base time of the elements so that they wait an additional delay
amount of time before starting to process buffers and cannot be
GST_CLOCK_TIME_NONE
.
This option is used for tuning purposes and should normally not be used.
MT safe.
delay
the delay
fn set_latency(&self, latency: ClockTime)
Sets the latency that should be configured on the pipeline. Setting GST_CLOCK_TIME_NONE will restore the default behaviour of using the minimum latency from the LATENCY query. Setting this is usually not required and the pipeline will figure out an appropriate latency automatically.
Setting a too low latency, especially lower than the minimum latency from the LATENCY query, will most likely cause the pipeline to fail.
latency
latency to configure
fn use_clock<P: IsA<Clock>>(&self, clock: Option<&P>)
Force self
to use the given clock
. The pipeline will
always use the given clock even if new clock providers are added
to this pipeline.
If clock
is None
all clocking will be disabled which will make
the pipeline run as fast as possible.
MT safe.
clock
the clock to use
fn connect_property_auto_flush_bus_notify<F: Fn(&Self) + Send + Sync + 'static>(
&self,
f: F
) -> SignalHandlerId
&self,
f: F
) -> SignalHandlerId
fn connect_property_delay_notify<F: Fn(&Self) + Send + Sync + 'static>(
&self,
f: F
) -> SignalHandlerId
&self,
f: F
) -> SignalHandlerId
fn connect_property_latency_notify<F: Fn(&Self) + Send + Sync + 'static>(
&self,
f: F
) -> SignalHandlerId
&self,
f: F
) -> SignalHandlerId
Implementors
impl<O: IsA<Pipeline>> PipelineExt for O
[src]
fn auto_clock(&self)
[src]
fn get_auto_flush_bus(&self) -> bool
[src]
fn get_delay(&self) -> ClockTime
[src]
fn get_latency(&self) -> ClockTime
[src]
fn get_pipeline_clock(&self) -> Option<Clock>
[src]
fn set_auto_flush_bus(&self, auto_flush: bool)
[src]
fn set_delay(&self, delay: ClockTime)
[src]
fn set_latency(&self, latency: ClockTime)
[src]
fn use_clock<P: IsA<Clock>>(&self, clock: Option<&P>)
[src]
fn connect_property_auto_flush_bus_notify<F: Fn(&Self) + Send + Sync + 'static>(
&self,
f: F
) -> SignalHandlerId
[src]
&self,
f: F
) -> SignalHandlerId
fn connect_property_delay_notify<F: Fn(&Self) + Send + Sync + 'static>(
&self,
f: F
) -> SignalHandlerId
[src]
&self,
f: F
) -> SignalHandlerId
fn connect_property_latency_notify<F: Fn(&Self) + Send + Sync + 'static>(
&self,
f: F
) -> SignalHandlerId
[src]
&self,
f: F
) -> SignalHandlerId